Technical data Documentation Request info

RinNova Cond completes the range of BIASI pre-mix condensing boilers, perfect for radiator systems and suitable for radiating systems with mixing units.

RinNova Cond is a compact condensing boiler, which ensures high efficiency, low energy consumption and respect for the environment.
It is available in the versions for heating and DHW production, with a heat output of 24, 28 and 32 kW.

Main features

  • Primary condensing exchanger in stainless steel with steel coating to offer maximum resistance to corrosion
  • Pre-mix burner in stainless steel (NOx class 6)
  • Modulation 1:5 Methane and also LPG
  • DHW exchanger with stainless steel plates
  • 7-litre expansion vessel
  • High-efficiency pump with low energy consumption
  • Integration with BIASI solar systems with a solar kit
  • Digital pressure reading display
  • Provision for remote control and external probe

Compact brass hydraulic unit. Delivery unit with motorised diverter, by-pass and system filling valve built in.
ErP pump with manual pump release on return unit.

Control panel operation

  • Summer/winter/off selector
  • Heating temperature regulator
  • DHW temperature regulator
  • Digital pressure reading
  • Screen display of DHW and heating temperature
  • Fault diagnostics, lockout conditions and fault log display

The display works in the following modes:

  1. INFO
    Information on the operating status and alarm history
  2. FREE PROGRAMMING
    Parameters can be programmed to adapt boiler/system and user SET
  3. INSTALLER PROGRAMMING
    Generator parameters
  4. SUPPORT PROGRAMMING
    Authorised service centre parameters

Remote controls

The RinNova Cond range has two remote class V commands, in the Basic and Top versions, with a weekly programmable thermostat with up to 4 programmable time periods with independent temperatures. All the information on the boiler display can also be viewed remotely.

Technical data

Nominal heating/DHW heat input
kW
21,0 / 25,0
Minimum heat input for heating/DHW
kW
5,1
Maximum usable heating/DHW power 60°/80°C *
kW
20,6 / 24,6
Minimum usable heating/DHW power 60°/80°C *
kW
4,8
Maximum usable heating/DHW power 30°/50°C **
kW
22,6 / 26,9
Minimum usable heating/DHW power 30°/50°C **
kW
5,3
Quantity of condensate at Q.nom. 30°/50°C (in heating mode) **
l/h
4
Quantity of condensate at Q.min. 30°/50°C (in heating mode) **
l/h
0,8
Condensate pH
4,0
Nom. efficiency 60°/80°C *
%
98,2
Min. efficiency 60°/80°C *
%
94,1
Nom. efficiency 30°/50°C **
%
107,5
Min. efficiency 30°/50°C **
%
104,9
Efficiency at 30 % load **
%
109,1
Energy efficiency ηs
%
93
Thermal losses at the flue with burner in operation
Pf (%)
1,6
Thermal losses at the flue with burner turned off ΔT 50°C
Pfbs (%)
0,2
Thermal losses to the environment through the casing with the burner in operation
Pd (%)
0,2
NOx class
6
Weighted NOx [Hs] ***
mg/kWh
33
Minimum/maximum heating temperature ****
°C
25 / 85
Minimum/maximum heating pressure
bar
0,3 / 3,0
Available heating head (at 1000 l/h)
mbar
385
Expansion tank capacity (total/usable)
l
7
Minimum/maximum DHW temperature
°C
30 / 60
Minimum/maximum DHW pressure
bar
0,3 / 10
Maximum flow rate (Δt = 25 K) / (Δt = 35 K)
l/min
14,3 / 10,0
Specific DHW flow (Δt = 30 K) *****
l/min
12,0
Voltage/power draw at nominal heat input
V~/ W
230 / 91
Power draw at minimum heat input
W
14
Power draw in stand-by
W
3,3
Ingress protection
IPX5D
Minimum/maximum flue gas temperature#
°C
52 / 82
Minimum/Maximum flue gas mass flow rate #
kg/sec
0,0025 / 0,0111
Minimum/maximum air mass flow rate #
kg/sec
0,0024 / 0,0107
Max. length of coaxial flue outlet (Ø 60/100 mm / Ø 80/125 mm)
m
10 / 14
Max length of twin flue exhaust (Ø 80+80 mm)
m
40
Height x Width x Depth
mm
700 x 400 x 300
Weight
kg
29,3
Water content of the boiler
l
2,0
Fuel
Metano (G20) - Propano (G31)

* With return water temperatures that do not allow condensation.
** With return water temperatures that allow condensation.
*** With coaxial flue outlet 60/100 L 0.9 m and G20 natural gas.
**** At minimum usable power.
***** With reference to EN 625.
# Values relate to tests with 80 mm 1 + 1 twin flue and G20 natural gas.

Documentation

×

Write us if you would like more information

Please select an option
Have you already tried to search on one of this page?


Otherwise continue with the compilation of the form.
To attach a file
Please select an option
Enter the email
Invalid Input
Select a country
Invalid Input
Insert your request
Privacy consent is missing
Chiudi